Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

3500/40M Proximitor Monitor

The 3500/40M Proximitor Monitor is a four-channel device that interfaces with Bently Nevada proximity transducers. It conditions signals for vibration and position measurements and compares them with user-configurable alarms. Through 3500 Rack Configuration Software, each channel can be programmed to perform various functions such as:

  • Radial vibration
  • Eccentricity
  • REBAM
  • Thrust position
  • Differential expansion

The primary function of the 3500/40M Proximitor Monitor is to provide continuous machinery protection by comparing monitored parameters against user-defined alarm setpoints. This allows for early detection of issues and ensures safe machine operation. Additionally, it offers valuable machine information for both operational and maintenance personnel.

Key Features

  • Machinery Protection: Continuously compares monitored parameters to alarm setpoints.
  • Versatile Measurements: Can measure radial vibration, eccentricity, thrust position, differential expansion, and REBAM.
  • Configurable Setpoints: Alerts and danger setpoints can be configured for each active static value.
  • Signal Conditioning: Conditions input signals to generate relevant machine parameters for monitoring.

Specifications

Inputs

  • Signal Inputs: Accepts from 1 to 4 proximity transducer signals.
  • Input Impedance: 10 kΩ (Standard I/O for proximitor and acceleration inputs).

Sensitivity

  • Radial Vibration: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
  • Thrust: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
  • Eccentricity: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
  • Differential Expansion: 0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil).
  • REBAM: 40 mV/μm (1000 mV/mil) or 80 mV/μm (2000 mV/mil).

Outputs

  • Front Panel LEDs:
    • OK LED: Indicates proper operation.
    • TX/RX LED: Indicates communication with other 3500 rack modules.
    • Bypass LED: Indicates Bypass Mode.
  • Buffered Transducer Outputs:
    • Each monitor has a coaxial connector for each channel.
    • Short-circuit protected.
    • Output Impedance: 550 Ω.
  • Transducer Power Supply: -24 Vdc.

Signal Conditioning

  • Frequency Response (Radial Vibration):
    • Direct filter: User-programmable single-pole from 4 Hz to 4000 Hz or 1 Hz to 600 Hz.
    • Gap filter: -3 dB at 0.09 Hz.
    • 1X Filter: Not used.
    • Constant Q Notch Filter: Minimum rejection in the stopband of -34.9 dB.
    • 1X and 2X Vector Filter: Constant Q Filter with a stopband rejection of -57.7 dB.

Power Consumption

  • Typical: 7.7 Watts.

Learn More

Click here to view the full datasheet

Leave a message